Schneider Altivar Solar
The drive that runs and meters the pump. Inject a fault and watch the response.
Schneider Electric
Altivar Solar ATV320
Modbus ID 1 · 19200 8E1
simulated drive SIMULATED
simulated drive SIMULATED
RDY
0.0Hz
0.00 kW0.0 A0 kWh
RDY
RUN
FLT
Telemetry, register by register
addresses from the ATV320 Modbus manual NVE41308
| Value | Register | Reading |
|---|---|---|
| State (ETA) | ETA @3201 | – |
| Output frequency | RFR @3202 | – Hz |
| Motor speed | RFRD @8604 | – rpm |
| Motor current | LCR @3204 | – A |
| Motor power | OPR @3211 | – % nom. |
| Motor voltage | UOP @3208 | – V |
| Drive thermal state | THD @3209 | – % |
| Energy | APH + UNT @3230 | – kWh |
| Last fault | LFT @7121 | – |
No published Modbus address exists for PV voltage, PV power, MPPT state or the drive's own flow estimate; they are marked UNVERIFIED and never read over Modbus: .
The drive is the meter
MODEL
Water is estimated from the drive's frequency (pump curve, affinity laws) and cross-checked with its power. A flow meter is needed only to calibrate: fitted factor k = . Below kW the pump lifts no water, so the planner sends that sun to the mill or batteries.
Saur Mitra Copilot: guided fix
no fault
Inject a fault on the faceplate. The Copilot reads the fault code from the drive (register LFT) and walks the Saur Mitra through the fix, step by step.