Schneider Altivar Solar

The drive that runs and meters the pump. Inject a fault and watch the response.

Schneider Electric
Altivar Solar ATV320
Modbus ID 1 · 19200 8E1
simulated drive SIMULATED
RDY
0.0Hz
0.00 kW0.0 A0 kWh
RDY
RUN
FLT

Telemetry, register by register

addresses from the ATV320 Modbus manual NVE41308
ValueRegisterReading
State (ETA)ETA @3201–
Output frequencyRFR @3202– Hz
Motor speedRFRD @8604– rpm
Motor currentLCR @3204– A
Motor powerOPR @3211– % nom.
Motor voltageUOP @3208– V
Drive thermal stateTHD @3209– %
EnergyAPH + UNT @3230– kWh
Last faultLFT @7121–

No published Modbus address exists for PV voltage, PV power, MPPT state or the drive's own flow estimate; they are marked UNVERIFIED and never read over Modbus: .

The drive is the meter

MODEL

Water is estimated from the drive's frequency (pump curve, affinity laws) and cross-checked with its power. A flow meter is needed only to calibrate: fitted factor k = . Below kW the pump lifts no water, so the planner sends that sun to the mill or batteries.

Saur Mitra Copilot: guided fix

no fault

Inject a fault on the faceplate. The Copilot reads the fault code from the drive (register LFT) and walks the Saur Mitra through the fix, step by step.